Hunter 44157 manual >>Download / Read OnlineAfter all wires are labeled, disconnect each wire and remove the existing wall plate. 11 INSTALLING THE THERMOSTAT Y W RC G 12 INSTALLING THE WALL PLATE 1.Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2.Position the new wall plate on the wall and pull the labeled wires through the.
“Setup” on page 10 of your owner’ s manual to continue setup, scheduling, and daily use. If you have any additional questions or problems with your Hunter. Thermostat, please call: USA: 1-888-830-1326. Canada: 1-866-268-1936. Hours of operation are from 7:00 am to 7:00 pm Monday - Friday. Sep 09, 2016 You can only set two programs with 5-2 thermostats like the 44157 - one for the weekdays and another for the weekends. That means this Hunter thermostat is fairly limited in terms of features. Begin by installing the base first. Thread the low-voltage wires through the specified opening of the new thermostat base. If your new thermostat is not self-leveling, use a small level to make sure it's properly aligned. Mount the thermostat base on the wall using the screws included with the thermostat.
The Hunter 42122 is a universal thermostat that is compatible with the following systems The Hunter Universal 42122 Non-Programmable Thermostat easily installs in 5 minutes. This Hunter thermostat fea via YouTube Capture. HEAT WON'T TURN ON How Test if your Thermostat is Broken Faulty Bad Zone Valve Boiler Furnace Repair - Duration: 2:36. You can Fix It!!!! 268,436 views In Hunter thermostats, auto recovery lets the furnace recover from an energy saving set point to a comfort set point, like too hot to comfortable. So it flashes the time until the issue is resolved. These model numbers include the 44157, 44110 and 44155, all of which do pretty much the same thing. Another series of Hunter thermostats are seven-day programmable models, which allow you to set each day of the week differently. These seven-day models include the 44377, 44378, 44550 and 44668. Hunter Fan 44127 Thermostat pdf manual download. 44127, 44132 Programmable Thermostat. Hunter Programmable Thermostat Model 44157 New, Hunter 44132 5 Minute 5 2 Household Thermostats, Hunter Non Programmable Thermostat Universal. Hunter Universal 44132 Programmable Thermostat Manual >>>CLICK HERE< Hunter 44860 Universal 2H/2C Touchscreen Thank you for your consideration of this NEW SEALED Hunter Set & Save Programmable Thermostat. This is model 44157. Payment is expected within 3 days of end of auction. I pride myself on speedy shipping. Thank you for looking and happy bidding! Hunter Douglas installation and operation manuals. If you need assistance, please contact one of our Customer Information Product Specialists at (800) 789-0331. Hunter 44157 Thermostat also features an INDIGLO Night-Light as a backlight that displays for easy viewing in the dark. Hunter 44157 - Universal 5/2-Day Programmable Thermostat will provide years of reliable service and year-round energy savings! Includes two #8 slotted screws and two wall anchors for mounting. Read and download Hunter Thermo
Siemens lfl 1.635 manualPanasonic vrf installation manualcheap air ticketsRec onlineinternational 464 service manual2008 dodge sprinter repair manualKia sedona 2011 repair manualAir cadet band drill manualHow to drive by insecnegocios de manualidades exitososUniversity of south carolina student handbookDir 835 manualSamsung sr-s2028css fault codessoundcraft si expression 3 manual
How To Program A Hunter Thermostat Model 44110
Some common technical issues of Hunter thermostats are mentioned in these tables. Here, you can find possible technical problems and the ways to fix the issues on one’s own. The troubleshooting instructions were provided by the manufacturer. Each manual is written in layman’s terms and is easy to follow: step-by-step instructions will help you to solve issues without repairmen’s help.
Hunter 42203 Thermostat Troubleshooting
Problem | Cause |
---|
My display does not appear. | Check the batteries and battery connections. |
Reset the thermostat. |
The auto fan feature does not operate properly. | Check to see if the correct furnace type is selected under the system settings in options. |
My display is erratic. | Replace the batteries. |
The program will not change at my desired setting. | Check that the time is set properly to AM and PM. |
Make sure the thermostat is not in permanent override mode. |
Check that the day setting is correct. |
Check that the time is set properly to AM and PM. |
The heating or cooling will not turn on or off | Make sure the thermostat is not in permanent override mode. |
Wait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor. |
Check circuit breakers and switches to ensure there is enough power to the system. |
Replace batteries. |
If applicable, make sure the furnace blower door is closed properly. |
If your system has 4 wires, ensure the jumper is installed between the RC and RH terminals. |
The display comes on but does not stay illuminated | Replace batteries. |
My system continues to operate when the thermostat is in the off position | Replace unit. |
Hunter 40135 Thermostat Troubleshooting
Problem | Cause |
---|
My heating or cooling will not turn on or off | Check the HE/HG Switch to ensure it is set to the correct position |
Wait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor |
Check the circuit breakers and switches to ensure there is enough power to the system |
Replace the batteries with fresh AA alkaline batteries |
If applicable, make sure the furnace blower door is closed properly |
. If your system has 4 wires, ensure the jumper wire is installed between the RC and RH terminals |
My system continues to operate when the thermostat is in the off position | Replace unit |
Hunter 44200 Thermostat Troubleshooting
Problem | Solution |
---|
SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers) | 1. Remove clear mylar sticker. |
NO DISPLAY | 1. Check battery connections and batteries. |
2. Press reset button once with a small pin and hold in for two seconds. |
ENTIRE DISPLAY DIMS | 1. Replace batteries. |
PROGRAM DOES NOT CHANGE AT YOUR DESIRED SETTING | 1. Check that time is set properly to 'AM' or “PM.' |
2. Check that thermostat is not in 'HOLD' mode. |
3. Check for correct day setting. |
AUTO/FAN DOES NOT COME ON | 1. Move HG/HE system selector to opposite position. |
Hunter Thermostat Manual 42999
Hunter 42177 Thermostat Troubleshooting
How To Install A Hunter Thermostat Model 44157 Manual
How To Install A Hunter Thermostat Model 44157 Model
Problem | Solution |
---|
No display | Check battery connections and batteries |
Press RESET button with a small pin and hold in for two seconds |
Entire Display Dims | Replace Batteries |
Auto / Fan does not turn on | Move HG/HE switch to opposite position |
Heating or Cooling Does Not Go On or Off | Check that the function switch is in the correct position ('HEAT' or 'COOL') |
There may be as much as 4-minute delay before the system turns On - wait a check. (Compressor protection delay.) |
Check your circuit breakers and switches to ensure there is power to the syste |
Replace batteries |
Make sure your furnace blower door is closed properly |
Thermostat permanently reads 'HI', 'LO', or 'Er' | Press the reset button once with a small pin and hold for two seconds |
Hunter 44260 Thermostat Troubleshooting
Problem | Solution |
---|
No Display | Check battery connections and batteries. |
Press RESET button with a small pin and hold in for two seconds |
Entire Display Dims | Replace Batteries |
Program Does Not Change at your Desired Setting | Check that the time is set properly to 'AM' or 'PM'. |
Check that the thermostat is not in Permanent HOLD mode. |
Check for the correct day setting. |
Auto Fan Does Not Turn On Properly | Move HG/HE selector to correct position. |
Heating or Cooling Does Not Go On or Off | Check that the function switch is in the conect position ('HEAT' or 'COOL'). |
There may be as much as 4-minute delay before the system turns On - wait and check. (Compressor protection delay.) |
Check your circuit breakers and switches to ensure there is power to the system. |
Replace batteries. |
Make sure your furnace blower door is closed properly. |
If your non-heat pump system only uses 4-wires, be sure the jumper wire is installed between the RC and RH terminals. |
Check the position of the System Selector switch: Standard or Heat Pump. |
Erratic Display | Press the reset button once with a small pin and hold for two seconds. Then reprogram. |
If unit continues to operate in the Off position | Replace unit. |
Thermostat permanently reads 'HI', 'LO', or 'ERR' | Replace unit. |
Hunter Thermostat 44905 Troubleshooting
Hunter Thermostat Lowe's
Problem | Solution |
---|
No display | Check battery position and battery life |
Program does not change at desired setting | 1. Check the time in all programs for proper AM/PM time. |
2. Ensure thermostat is not in 'Save Away' mode. |
3. Make sure the thermostat is set to the proper day |
Auto / Fan does not turn on | 1. Check the HG/HE setting under System in Menu options. |
2. Check the fan setting and make sure that it is not set to off |
Fan runs continuously | 1. Check fan setting to see if it is set to on. |
2. Check the HG/HE setting under System in Menu options |
Heating or cooling does not turn on or off | 1. Check the system is in the right mode (heat or cool). |
3. Be sure to wait up to 4 minutes for system protection if your system was just on. |
4. Check breakers to make sure power is getting to your system |
5. Replace the batteries |